Data Systems Plus
Data Systems PlusAbout  Data Systems PlusRequest a QuoteContact Data Systems PlusSite Map

3270 Terminals
Thin Clients
Printronix


IBM 3151-610 IBM ASCII Display
IBM 3151-610 IBM ASCII Display

The 3151 IBM ASCII Display Station is a stand-alone, high-quality, 14-inch, monochrome display station used for displaying up to 3,300 characters and for entering data into and retrieving data from a host processor. The IBM 3151 14-inch monitor has an actual viewable screen size of 11.4 inches when measured diagonally. The 3151 also communicates with the 128 7-bit ASCII/ISO character set or the 256 8-bit ASCII/ISO character set, depending on machine mode and language. The 3151 is offered in a range of models featuring an asynchronous communication interface with a 7-bit or 8-bit word length, using RS-232-C (CCITT V.24/28) interface expandable to additional RS-422-A (CCITT V.11) interface. The 3151 provides a native mode, 3101 mode, and various emulation modes that allow the 3151 to attach to a variety of host processors. The 3151 native mode is compatible with the native modes of the 3161 or the 3162 with limitations.

Model Abstract 3151-610

The 3151 IBM ASCII Display Station Model 610 offers Amber-gold phosphor colors and a 80/132 character column display. It is IBM PS/2 compatible, with a 101-key keyboard, and has customer-recappable keytops. The RS-232-C or RS-422-A main port is interface-selectable by the user or host application with speeds up to 38.4K bps and has DTR pacing for outbound data in RS-232-C. The Model 610 also offers a choice of four machine modes by the operator or host: IBM 3151 Echo mode, IBM 3151 PC mode, IBM 3151 PC II mode, and 925PC mode. The IBM 3151 Echo mode is a superset of IBM 3161 ASCII Display Station, operating in Echoplex, but does not support definable F-keys and Local mode. The outbound data stream of the IBM 3151 PC and IBM 3151 PC II modes is a 3151 Echo mode data stream modified to Code Page 00437 (IBM 3151 PC) and Code Page 00850 (IBM 3151 PC II). The inbound data stream of the IBM 3151 PC mode and 3151 PC II mode is the IBM PS/2 Set 1 Scan Codes. The outbound data stream of 925PC modes is a subset of TeleVideo 925 data stream modified to Code Page 00437. The inbound data stream of 925PC modes is the IBM PS/2 Set 1 Scan Codes or Code Page 00437. Functions " Compact design " 14-inch, etched screen display. The IBM 3151 14-inch monitor has an actual viewable screen size of 11.4 inches when measured diagonally. " 24 lines or 25 lines of data display plus one line display for operator indicator " RS-232-C communication with speeds up to 38.4K bps " Bidirectional, smooth and jump scroll " Concurrent support of character attributes (for blink, non-display, underline, reverse and high intensity) and field attributes (for normal, blink, non-display, underline, reverse, high intensity, protected, numeric, and modified data tag) in IBM 3151 Echo, IBM 3151 PC, and IBM 3151 PC II modes include a Microsoft or compatible mouse attachment to the auxiliary port, commands for window presentation assist (Box, Rectangle, Rectangle Copy, Fill Character/Attribute into Rectangle), functions emulating Interrupt 10H routines of the IBM PC System BIOS, and an ANSI X3.64 type buffer/cursor addressing command.

Highlights

  • Compact design
  • 14-inch, etched screen display. The IBM 3151 14-inch monitor has an actual viewable screen size of 11.4 inches when measured diagonally.
  • 24 lines or 25 lines of data display plus one line display for operator indicator
  • RS-232-C communication with speeds up to 38.4K bps
  • Bidirectional, smooth and jump scroll
  • Concurrent support of character attributes (for blink, non-display, underline, reverse and high intensity) and field attributes (for normal, blink, non-display, underline, reverse, high intensity, protected, numeric, and modified data tag)

Model Description 3151-610

The 3151 Model 61X displays 1,920 (80 by 24), 2,000 (80 by 25), 3,168 (132 by 24) and 3,300 (132 by 25) characters. An alphameric character is represented in a character cell of 9 x 15 or 9 x 14 dot matrix. The data displayed uses the 128 characters of the 7-bit ASCII/ISO codes and an additional character set containing 24 line-drawing graphics, ten script characters, and ten subscript characters. A line drawing character is represented in a 9 x 15 or 9 x 14 dot matrix to create a contiguous line. Echo-transmission mode provides the capability to transmit a character over a communication line upon depression of each key.

System Attachment

Series/1, System/88, 9370, and non-IBM mini-computers attach the 3151 with RS-232-C CCITT V.24/28) interface, or RS-422-A (CCITT V.11) interface both in 50 to 19.2K bps line speed, or via a modem with RS-232-C (CCITT V.24/28) interface. The 3151 attaches to Series/1 with Multi-function attachment feature (#1310) in RS-232-C and RS-422-A, with Feature-programmable 4-line Adapter feature (#2096) in RS-232-C, or with Asynchronous Terminal 8-Line Adapter (RPQ D02350) in RS-422-A. S/370 Processors attach the 3151, via 270X, 370X, or 3725/6 with RS-232-C (CCITT V.24/28) interface in 50 to 1200 bps line speed, via 370X/8100, 3725/8100 or 3726/8100 with RS-232-C (CCITT V.24/28) interface in 50 to 9600 bps without modem and in the modem speeds (but not exceeding 9600 bps) with modem, and via a protocol converter with RS-232-C (CCITT V.24/28) interface in 50 to 19.2K bps line speed.

The System/36, System/38, and AS/400 attach the 3151 with RS-232-C (CCITT V.24/28) interface or RS-422-A (CCITT V.11) interface both in 110 to 19.2K bps line speed. The S/36-38 attachment is via the 5208 ASCII-5250 Link Protocol Converter or ROLMbridge 5250 Link Protocol Converter. The 3151 can be attached to the 6150/6151 via the 4-port Asynchronous 232-C Adapter or 4-port Asynchronous 422A Adapter (see Note), and operate in native mode in 50 to 19.2K bps line speed.

The 3151 can be attached to the IBM Personal System/2 via its resident Asynchronous RS-232-C port, via Dual Asychronous Adaper/A (#3033) (6450347) in RS-232-C. or via an IBM Multiport/2 Adapter (#6263) in RS-232-C and RS-422-A.

The 3151 may be attached to a 4361 processor via the 4361 feature EIA/CCITT interface (#3701) with the 4361 feature Line Attachment Base for Non-clocked Modems (#4696). It may operate at speeds up to 2,400 bps, in 3101 mode and 3151 native mode. The attachment must be via the EIA RS-232-C (CCITT V.24/28) interface, either via asynchronous modem with switched or nonswitched telephone line, or via direct attachment at distance up to 12m (40 ft).

For direct connection to the 8100 system a modem cable must be used, with extension to the 8100 direct connect cable not exceeding 9.1m (30.0 ft). The total maximum cable length from the 8100 system to the 3151 may not exceed 12.2m (40.0 ft).

 
Data Systems Plus can provide fast accurate Sell, Lease, or Rent quotes for your company's desired configurations. Presales consultation/assistance is always available. Please email or call for Quote.