The 3174 Model 63R is a table-top remote controller that supports the
IBM Cabling System interface for IBM Token-Ring Network attachment. The
Model 63R supports up to sixteen 3270 devices and eight ASCII devices.
Terminal Attachment
The 3174 Establishment Controllers offer a wide variety of terminal attachments.
They can be configured to connect terminals directly, via 3299 Terminal
Multiplexers, via optional Terminal Multiplexer Adapters (#3103) and via
optional Telephone Twisted Pair Terminal Multiplexer Adapters (#3105),
or by a combination of these attachments.
Models 61R, 62R, 63R and 64R have a maximum attachment capability of
16 terminals. The base controller has an integrated nine-port terminal
adapter which permits up to nine terminals to be directly attached, or
by using one of the following, up to a maximum of 16 terminals can be
attached:
- Two 8 port multiplexers (3299 model 002 and 003)
- One 8 port multiplexer and up to eight terminals directly attached
Communications Facilities
3174 Models 11R, 12R, 21R, 61R, 62R, 90R, 91R, and 92R operate in data
half-duplex point-to-point or multipoint modes on duplex or half-duplex
nonswitched facilities, and in half-duplex point-to-point mode on switched
facilities as listed below.
COMMUNICATION FACILITIES 3174 MODEL 11R/21R/61R/90R/91R:
|
Electrical Interface
|
Facility (see 2700 pages)
|
Link/Network Protocol
|
Max. speed (bps)
|
| EIA EIA232-D / CCITT V.24/28 (External clock
required) |
D,G
|
BSC @
|
19.2K |
|
C,D,E,G
|
SNA/SDLC
|
19.2K |
|
K,M
|
SNA/SDLC (x.21bis)
|
19.2K |
|
P
|
x.25 @ (x.21bis)
|
19.2K |
| CCITT V.35 (External clock required) |
D,G
|
BSC @
|
19.2K |
|
D,E,G
|
SNA/SDLC
|
64K |
|
M
|
SNA/SDLC
|
256K |
|
P
|
x.25 @ (x.21bis)
|
64K |
@ = Not available on Model 90R.
NOTE: When ordering this controller a Communication cable must be specified:
V.24 or V.35.
|